| Power Supply |
AK-UCU600PJ/
AK-UCU600PSJ |
100 V - 120 V AC, 50 Hz/60 Hz |
AK-UCU600EJ/
AK-UCU600ESJ |
100 V - 240 V AC, 50 Hz/60 Hz |
| Power Consumption |
500 W (Without camera connected: 90 W) |
| Capacity for Supplying Power to a Camera |
240 V AC (tolerance: 5 %), 1.46 A , 50 Hz / 60 Hz |
| Operating Temperature |
0 ℃ to 40 ℃ (32 °F to 104 °F) |
| Operating Humidity |
10 % to 90 % (no condensation) |
| Weight |
Approx. 8.9 kg (19.6 lb) |
| Dimensions (W x H x D) |
424 mm x 88 mm x 401 mm (16-5/8 inches x 3-7/16 inches x 15-13/16 inches)
(excluding protrusions) |
| Video Output |
3G/HD-SDI |
5 lines (embedded audio is supported only for HD signals) |
| 12G/6G/3G/HD-SDI |
2 lines |
| HD-SDI |
1 line (shared with picture monitor output*1) |
| Analog composite |
2 lines (1 line shared with picture monitor output*1)
* For details on output formats, please see the "Supported formats". |
| HD TRUNK/TICO Output |
HD-SDI |
1 line (HD TRUNK output) |
| 3G/HD-SDI |
1 line (TICO output) |
| Return Input |
3G-HD/HD/SD-SDI |
4 lines (RET1 input has active-through output) |
| Analog composite |
1 line |
| Prompter Input |
HD-SDI |
1 line (with active-through output) |
| Analog composite |
2 lines (through output of 1 and input of 2 share the connector*1)
It is not terminated when the unit is turned OFF. No through output. |
| Reference Input |
BB (black burst) / tri-level*2: 1 line
(automatic termination, connect to upper connector; BB signal and tri-level signal automatically recognized, with loop-through output) |
| Microphone Output |
0 dBm/600 Ω, 2 lines (XLR, 3-pin, male) |
| Communication |
Intercom input/output (ENG / PROD, 0 dBm, 600 Ω (4 W) /
1 V [p-p], 200 Ω (RTS), 4 W / RTS / CLRCOM) : 2 lines*1 |
| PGM input (0 dBm/600 Ω) : 2 lines |
| Tally input (red, green, yellow) : 1 input each |
| AUX |
WFM control
6-bit (open collector output, terminal shared with camera microphone gain setting*1) |
Camera microphone gain setting input
5-bit (photo-coupler input, terminal shared with WFM control*1) |
| Down-conversion system setting input 2-bit (photo-coupler input) |
| TRUNK |
RS-422 / RS-232C
2 lines*1 |
| FRONT ROP |
RS-422
1 line, 16 V DC output (only one of this and REAR ROP can be selected at one time via the menu
or the [ROP FRONT/ REAR] selection switch on the front panel) |
| REAR ROP |
RS-422
1 line, 16 V DC output (only one of this and FRONT ROP can be selected at one time via the menu
or the [ROP FRONT/REAR] selection switch on the front panel) |
| MSU |
RS-422
1 line, GPI for control |
| LAN TRUNK |
LAN connection with camera side via an optical cable*3
1 line, 100BASE-TX, 1000BASE-T |
| LAN |
Personal computer connection for distribution via the Web*3
1 line, 10BASE-T, 100BASE-TX (use a crossover cable when connecting directly with a personal computer) |